Skip to content

Cookie preferences

Choose what we may use. You can change this at any time through the "Cookie preferences" link in the footer. Learn more in our Privacy Policy

SARTORI Implants

Trauma

Titanium Locked Intramedullary Nail

ANVISA registration 80083650048

The commercial models that make up the Blocked Intramedullary Nail family consist of surgically invasive implants for long-term use, developed for application in bone fixation through intramedullary blocking, with the purpose of reducing, aligning, stabilizing...

Codes
78
Documents
1

Technical information

Everything the surgical team needs to know.

Overview

The commercial models that make up the Blocked Intramedullary Nail family consist of surgically invasive implants for long-term use, developed for application in bone fixation through intramedullary blocking, with the purpose of reducing, aligning, stabilizing and fixing various types of fractures, in medium and large bones, of lower limbs such as the femur and tibia, accompanied by a cap screw and anti-rotational locking screw (when applicable), and used in association with the ancillary components: Screw Blocking Device for Intramedullary Nail (ancillary component and not part of this product), according to the indication for use.

The Buffer Screws and the anti-rotational locking Screw (when applicable) form a single composite product with the Intramedullary Nails, maintaining an interdependent relationship to obtain the functionality and performance for which it is intended. Its function is to prevent bone formation and tissue invasion in the connecting part of the instrument, so as not to hinder removal, and cannot be sold separately.

The working principle of the intramedullary nail is similar to a tube within another tube, providing support and stability to the fixation. To achieve rotational stability, the rod relies on friction and interdigitation of fracture fragments, as well as contact extension for greater resistance to tilting and bending. To increase the contact area, intramedullary milling is often used, as this procedure enlarges the medullary canal to allow the insertion of the nail, in addition to being large enough to provide stability, it is also strong enough to assume the function of the bone, which is to act as a support structure and transmit load. This maintains or restores stability in the affected region, with the aim of preventing or correcting injuries of various etiologies.

The product consists of a semi-rigid fixation system in which the longitudinal component is a solid or cannulated Intramedullary Rod, accompanied by the Cap Screw and anti-rotational locking Screw (when applicable), with exclusive blocking by a transverse access screw called Locking Screw (ancillary component), in the Femoral and Tibial region. The product is designed to withstand axial compression, bending and torsional loads. In this way, it immobilizes the bones and transmits or relieves mechanical loads on the bone.

The product is characterized by supporting mechanical efforts in the required proportion, presenting an elastic modulus and interfaces with the bone, suitable for the transmission of forces in the bones, being biocompatible and adapting to the bone geometry of structures such as the tibia and femur.

Indications

The family of Locked Intramedullary Nails is used to perform bone fixation procedures through intramedullary blockage. It serves as a structural element within the medullary canal of long bones, in order to stabilize simple or complex fractures and pseudarthroses, in order to provide bone consolidation in the most physiological way possible.

The main objective of the Intramedullary Nail is to reduce, align, stabilize and fix different types of fractures, in medium and large bones, of the femur and tibia lower limbs.

Materials

Titanium Alloy ASTM F136

Components

Components and codes

78 codes available in this system. Search by code or description.

Components and codes of Titanium Locked Intramedullary Nail
Code Description ANVISA Qty
0072050-260HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.8X260, SOLID800836500481
0072050-270HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.8X270, SOLID800836500481
0072050-280HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.8X280, SOLID800836500481
0072050-290HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.8X290, SOLID800836500481
0072050-300HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.8X300, SOLID800836500481
0072050-310HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.8X310, SOLID800836500481
0072050-320HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.8X320, SOLID800836500481
0072050-330HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.8X330, SOLID800836500481
0072050-340HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.8X340, SOLID800836500481
0072050-350HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.8X350, SOLID800836500481
0072050-360HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.8X360, SOLID800836500481
0072050-370HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.8X370, SOLID800836500481
0072050-380HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.8X380, SOLID800836500481
0072050-390HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.8X390, SOLID800836500481
0072050-400HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.8X400, SOLID800836500481
0072051-260HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.9X260800836500481
0072051-270HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.9X270800836500481
0072051-280HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.9X280800836500481
0072051-290HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.9X290800836500481
0072051-300HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.9X300800836500481
0072051-310HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.9X310800836500481
0072051-320HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.9X320800836500481
0072051-330HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.9X330800836500481
0072051-340HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.9X340800836500481
0072051-350HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.9X350800836500481
0072051-360HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.9X360800836500481
0072051-370HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.9X370800836500481
0072051-380HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.9X380800836500481
0072051-390HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.9X390800836500481
0072051-400HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.9X400800836500481
0072052-260HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.10X260800836500481
0072052-270HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.10X270800836500481
0072052-280HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.10X280800836500481
0072052-290HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.10X290800836500481
0072052-300HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.10X300800836500481
0072052-310HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.10X310800836500481
0072052-320HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.10X320800836500481
0072052-330HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.10X330800836500481
0072052-340HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.10X340800836500481
0072052-350HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.10X350800836500481
0072052-360HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.10X360800836500481
0072052-370HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.10X370800836500481
0072052-380HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.10X380800836500481
0072052-390HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.10X390800836500481
0072052-400HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.10X400800836500481
0072053-260HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.11X260800836500481
0072053-270HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.11X270800836500481
0072053-280HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.11X280800836500481
0072053-290HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.11X290800836500481
0072053-300HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.11X300800836500481
0072053-310HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.11X310800836500481
0072053-320HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.11X320800836500481
0072053-330HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.11X330800836500481
0072053-340HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.11X340800836500481
0072053-350HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.11X350800836500481
0072053-360HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.11X360800836500481
0072053-370HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.11X370800836500481
0072053-380HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.11X380800836500481
0072053-390HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.11X390800836500481
0072053-400HASTE INTRAM. BLOQUEADA TIBIAL TI STD DIAM.11X400800836500481
0122020-025Parafuso de Bloqueio TI Ø4,5x25, Rosca Total, Autorroscante800836500621
0122020-030Parafuso de Bloqueio TI Ø4,5x30, Rosca Total, Autorroscante800836500621
0122020-035Parafuso de Bloqueio TI Ø4,5x35, Rosca Total, Autorroscante800836500621
0122020-040Parafuso de Bloqueio TI Ø4,5x40, Rosca Total, Autorroscante800836500621
0122020-045Parafuso de Bloqueio TI Ø4,5x45, Rosca Total, Autorroscante800836500621
0122020-050Parafuso de Bloqueio TI Ø4,5x50, Rosca Total, Autorroscante800836500621
0122020-055Parafuso de Bloqueio TI Ø4,5x55, Rosca Total, Autorroscante800836500621
0122020-060Parafuso de Bloqueio TI Ø4,5x60, Rosca Total, Autorroscante800836500621
0122020-065Parafuso de Bloqueio TI Ø4,5x65, Rosca Total, Autorroscante800836500621
0122020-070Parafuso de Bloqueio TI Ø4,5x70, Rosca Total, Autorroscante800836500621
0122020-075Parafuso de Bloqueio TI Ø4,5x75, Rosca Total, Autorroscante800836500621
0122020-080Parafuso de Bloqueio TI Ø4,5x80, Rosca Total, Autorroscante800836500621
0122020-085Parafuso de Bloqueio TI Ø4,5x85, Rosca Total, Autorroscante800836500621
0122020-090Parafuso de Bloqueio TI Ø4,5x90, Rosca Total, Autorroscante800836500621
0122020-095Parafuso de Bloqueio TI Ø4,5x95, Rosca Total, Autorroscante800836500621
0122020-100Parafuso de Bloqueio TI Ø4,5x100, Rosca Total, Autorroscante800836500621
0122020-105Parafuso de Bloqueio TI Ø4,5x105, Rosca Total, Autorroscante800836500621
0122020-110Parafuso de Bloqueio TI Ø4,5x110, Rosca Total, Autorroscante800836500621

Showing 10 of 78

Instructions for use

Instructions for use and documents

Official PDF files, with revision and ANVISA registration.

Quote

Request a quote.

Tell us what you need about Titanium Locked Intramedullary Nail. The Sartori sales team replies with a proposal, availability and technical support.

  • Direct contact with the factory sales team
  • Technical visits and complementary materials
  • For hospitals, distributors and surgeons
ProductTitanium Locked Intramedullary Nail

We reply during business hours. Your data is never shared.

Titanium Locked Intramedullary Nail
Support